We bring you a Refurbished HIRAYAMA – HG-50 Liter Digital Autoclave in Pakistan at Surgical Hut.
Digital High-Pressure Steam Sterilizer Autoclave Machine Features
-
Space-saving design with the lid opening upward.
-
Programmable auto-start for initiating a cycle up to 1 week later.
-
A dual-sensing lid interlock prevents lid opening when the chamber is pressurized or when the temperature exceeds 97°C.
-
Automatic air purging by a microprocessor prevents over-pressurization during a cycle.
-
One-touch lever to easily open and close the chamber lid.
-
Programmable rate of steam exhaust.
-
The door-closure sensor provides a prompt, and the process will not start unless the door is completed correctly.
-
The in-process display shows the status and progress of the sterilization cycle.
-
Agar sterilization mode for sterilizing agar and then automatically maintaining it at liquid temperature.
-
Unique accessory: A floating sensor to monitor load temperature.
-
The sterilization timer is activated only when the load reaches the set temperature.
-
Agar melting mode for rapidly melting agar and maintaining it at liquid temperature or for a hot and faster start-up
-
Memory backup system retains user-programmed parameters even in case of power failure.
Specifications
MODEL | HV-50 | |
TEMPERATURE | ||
Operating Range | 105ºC to 135ºC | |
Display Range | 137ºC | |
Warming Range | 45ºC to 60ºC | |
Agar Dissolution | Heating at 60ºC to 100ºC for up to 1 hour (temperature and time programmable), followed by 45ºC to 60ºC (programmable for up to 20 hours to prevent coagulation) | |
GAUGE PRESSURE | ||
Operating Range | 3 to 30 psi (0.02 to 0.206MPa) | |
Maximum Allowable | 38 psi (0.26MPa) | |
TIMER | ||
Sterilization | 1 to 250 minutes | |
Delayed Auto-start | 1 minute | |
DIMENSIONS | ||
Overall (W x D x H) | 20″ x 21″ x 41″ (51 cm x 53 cm x 104 cm) | |
Chamber (Diameter x Height) | 50 litres 11.8″ x 28.0″ (30 cm x 71 cm) | |
SAFETY DEVICES | Dual-sensing lid interlock, over-pressure power cutoff, over-temperature power cutoff, low-water power cutoff, mechanical pressure relief valve, microprocessor-controlled pressure relief valve, lid-closure detector, over-current detector and circuit breaker | |
PROGRAMS | ||
1. For agar | Heating -> Sterilization -> Exhaust (from no exhaust to slow) -> Warming -> Completion | |
2. For liquids | Heating -> Sterilization -> Exhaust (from no exhaust to slow) -> Completion | |
3. For solids | Heating -> Sterilization -> Exhaust (fast, default) -> Completion | |
4. For melting agar or for faster start-up | Rapid melting at 60°C to 100°C (temperature and time programmable) -> Maintain at 45°C to 60°C (temperature programmable) -> Completion | |
ACCESSORIES | ||
Stainless steel | Mesh wire baskets, buckets (pails), and round test tube racks | |
Factory or field installed | Floating (load) sensor, digital printer, and data logger | |
POWER | ||
Source | 120V, 50/60 Hz (220V/240V available) | |
Consumption | 2000 watts (20000VA) | |
SHIPPING WEIGHT | 180 lb (82 kg) |
WARRANTY: 6-month warranty.
Buy Now and Experience the best sterilization with our Digital autoclave machine with a 6-month warranty.